Home > Knowledge > PG1300-20/520 Fixed Plate-Fin Radiator for Oil-Immersed Transformers | TengQi Technology

Transformer Applications for the PG1300-20/520 Fixed Plate-Fin Radiator

TengQi Technology(TQT)
2026-09-14
Industry Research
The TengQi Technology PG1300-20/520 fixed plate-fin radiator is designed for natural cooling of oil-immersed transformers. It is suitable for 10 kV and 35 kV distribution transformers and selected small- to medium-capacity 110 kV power transformers. Learn about its structural specifications, outdoor installation applications, environmental adaptability, and key selection considerations.

TengQi Technology (TQT) offers the PG1300-20/520 fixed plate radiator for self-cooling oil-immersed transformers. The product features an integral welded SPCC structure, designed for transformer cooling needs in fixed installations. It can be used in 10kV and 35kV oil-immersed distribution transformers, and can also be adapted to small and medium-capacity 110kV power transformers, as well as some rectifier and traction transformers, depending on capacity, thermal design, tank interface, and project technical requirements.

For urban and rural power distribution networks, industrial and mining enterprises, power distribution facilities in civil buildings, and outdoor scenarios such as pole-mounted, platform-mounted, and prefabricated substations, this fixed transformer cooling solution can be used as a component of the oil tank heat dissipation system. Final compatibility should be based on transformer thermal calculations, structural verification, environmental ratings, and project technical documents.

Product positioning and supporting product range

Self-cooling heat dissipation for oil-immersed transformers

The PG1300-20/520 is a fixed plate-type heat sink. Its plate-type heat dissipation structure expands the heat exchange surface, providing self-cooling support for transformer oil temperature control. Its specific heat dissipation configuration needs to be confirmed in conjunction with the transformer's losses, temperature rise requirements, and cooling method.

Adaptable to fixed installation structure

The integral welded structure can be fixedly matched with the transformer tank, and is suitable for pole-mounted transformers, benchtop transformers, prefabricated substations and other equipment layouts with clear installation space and interface conditions.

Serving various power distribution and industrial scenarios

The products can be used in power distribution networks, industrial and mining enterprises, and building power distribution equipment; for special industrial transformers such as rectifiers and traction transformers, the configuration should be further evaluated based on the actual operating conditions, vibration conditions, and technical agreements.

Core technical parameters

project parameter
Product Model PG1300-20/520
Product Type Fixed plate heat sink
center distance 1300 mm
Number of slices and width of a single slice 20 pieces; 520 mm
Material and thickness SPCC; 1.0 mm
Product weight 242 kg
Self-cooling heat dissipation area 14.73㎡
Oil weight 59.84 kg
Coating and corrosion protection The total paint film thickness is 120μm, meeting the C3 corrosion protection requirements.
Minimum order quantity 1 40HQ

Note: Installation dimensions, tank interface type, valve and pipeline configuration, and tank conditions should be implemented in accordance with transformer design parameters, procurement technical documents, and technical agreements confirmed by both parties.

Structural design and operation and maintenance considerations

integral welded structure

The product employs an integral welding method, reducing the use of sealing nodes and gaskets, and lowering the risk of oil leakage during operation from a structural design perspective. Actual sealing performance should still be based on the manufacturing process, inspection results, and project acceptance requirements.

SPCC material and fixed accessories

SPCC material combined with a fixed installation method is suitable for structural matching with oil-immersed transformer tanks. For scenarios involving vibration, external impact, or special loads, support, connection, and structural verification should be completed during the project design phase.

To facilitate cleaning according to on-site specifications

In dusty outdoor environments, the wide fins and large channels of the plate-type structure help reduce dust accumulation. Maintenance personnel can inspect and clean the surface according to on-site safety procedures and equipment maintenance specifications; if high-pressure water washing is used, it should comply with equipment shutdown, insulation protection, and on-site management requirements.

Outdoor environmental adaptability

The PG1300-20/520 features an outdoor weather-resistant coating with a total paint film thickness of 120μm. Its corrosion resistance meets C3 requirements, making it suitable for outdoor environments with moisture, dust, and certain industrial corrosive factors. Product data indicates an applicable ambient temperature range of -5℃ to +45℃ , making it suitable as a fixed self-cooling heat dissipation component in high-temperature, high-humidity, and fluctuating load scenarios.

In coastal environments with high humidity, strong winds, thunderstorms, or industrial acid corrosion, the requirements need to be confirmed in conjunction with the local corrosion level, media conditions, wind resistance requirements, and project protection design. Reinforced fixed supports, equipotential grounding, and related protective configurations should be based on environmental parameters, structural verification, and technical agreements.

Typical application scenarios

  • 10kV and 35kV oil-immersed distribution transformers
  • Small and medium capacity 110kV oil-immersed power transformer
  • pole-mounted transformers and benchtop transformers
  • Oil-immersed transformer in prefabricated substation
  • Urban and rural power distribution networks and power distribution equipment in remote areas
  • Power distribution equipment for industrial and mining enterprises and civil buildings
  • Special industrial transformers such as rectifier transformers and traction transformers

Key points for selection confirmation

The parameters of the fixed plate heat sink should be compatible with the overall transformer design. To improve the accuracy of the PG1300-20/520 matching confirmation, it is recommended to clarify the following information during the technical communication phase:

  1. Thermal design conditions: transformer capacity, losses, cooling method, temperature rise requirements, and target heat dissipation capacity.
  2. Oil tank and interface conditions: installation location, center distance, connection interface, valve layout and pipeline matching requirements.
  3. Installation and transportation conditions: installation space, supporting structure, lifting method, packaging and destination transportation arrangements.
  4. Operating environment conditions: ambient temperature and humidity, dust, corrosive media, wind load, lightning and local protection level requirements.
  5. Inspection and delivery requirements: materials, coating, quality verification items, scope of supply and project acceptance documents.

Tengqi Technology's supporting services

Tengchi Technology can provide assistance with selection communication, technical consultation, sample development, mass production, quality verification, and delivery coordination for plate heat sinks, taking into account transformer models, cooling methods, installation space, and operating environment. The standard parameters, materials, and coating information for PG1300-20/520 can be used as a preliminary selection reference; the final scope of supply, interface requirements, inspection items, packaging and transportation, delivery conditions, and after-sales arrangements will be subject to the confirmed commercial and technical documents.

Leveraging its capabilities in the R&D, manufacturing, and quality verification of finned heat sinks, TQT, with its brand philosophy of " Upholding Integrity and Achieving Excellence ," provides transformer manufacturers, EPC contractors, power companies, and new energy customers with heat dissipation products tailored to their project needs.

Recommended Reading

Hot Products

Popular articles

PG1300-20/520 Fixed Plate-Fin Radiator for Oil-Immersed Transformers | TengQi Technology
PG1300-20/520 Fixed Plate-Fin Radiator for Oil-Immersed Transformers | TengQi Technology
PG1300-20/520 Fixed Plate-Fin Radiator for Oil-Immersed Transformers | TengQi Technology
PG1300-20/520 Fixed Plate-Fin Radiator for Oil-Immersed Transformers | TengQi Technology
ENGINEERING & MANUFACTURING

Need Radiator Selection or Custom Engineering Support?

Share your transformer parameters, cooling requirements or project conditions. TQT's engineering team will support product selection and customized solutions.

TQT Engineering SupportGlobal Supply · Custom Manufacturing · Technical Support